xFUME
TIG
4.5

Connecting the extraction hose

► Connect the extraction hose of the extraction system to the suction
connector on the cable assembly.
4.6

Connecting the shielding gas and setting the gas volume

1 Select the appropriate shielding gas for the welding task.
2 Briefly open the valve on the gas supply then close it again to air-blast
away any dirt on the connector.
5

Operation

WARNING
Risk of injury due to electromagnetic fields
The device can produce electromagnetic fields that could impact the proper function of cardiac pacemakers and implanted defibrillators.
► Do not use the device if you have a pacemaker or an implanted defibrillator.
► Only use the device in industrial zones in accordance with DIN EN 61000-6-3.
5.1

Handle operating elements

Handle modules
The trigger's 2-step and 4-step operating mode can be activated when using
a standard welding torch. The operating modes depend on the respective
power sources.
Tab. 4
Optional handle modules
Single function
Double function
BIS-51/S1
BIS-52
Air slide, Fig. 3
The extraction volume can be regulated during the welding process at the
air slide.
5.2

Welding

1 Open the shielding gas cylinder.
2 Switch on the power source.
3 Set the welding parameters.
4 Start the welding process and fume extraction according to the
configuration of the handle module.
5.3
Regulating the extraction volume, Fig. 3
► Observe the operating instructions for the fume extraction system.
► Push air slide to the rear (4) = close, max. extraction volume at the
suction nozzle.
6

Putting out of operation

NOTICE
Material damage due to overheating
Liquid-cooled cable assemblies may start leaking if overheated.
► Allow the cooling unit to continue running for approx. 5 min. after the welding process.
1 Stop the welding process.
2 Wait for the gas post-flow time to pass then switch off the welding
power source.
3 Connect the shielding gas to the welding device as per the
4 Adjust the shielding gas volume to the gas nozzle used and the welding
Additional handle modules can be integrated as an option. These must be
ordered separately. The handle modules functions are based on the
customer-specific connection configuration.
Up/Down BIS-55
Cover BIS-57
5 Move the welding torch uniformly over the entire seam length.
6 End the welding process and fume extraction according to the
► Push air slide to the front (3) = open, reduced extraction volume at the
3 Close the valve on the shielding gas cylinder.
4 Switch off the cooling unit.
manufacturer's instructions.
task and save the setting.
Up/Down BIS-65
Up/Down BIS-85
configuration of the handle module.
suction nozzle.
5 Operation
Up/Down BIS-95
EN - 35