Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel iROB 501 Originalbetriebsanleitung Seite 137

Schweißstromquelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

®
®
iROB
501, iROB
401, iROB
Tab. 19
Fault codes on the control panel and their remedy
Fault code
Type of fault
1 = alarm
2 = warning
E-
700
1
E-
710
1
E-
840
1
E-
950 to 956
1
E-
992 to 998
®
301
Cause of fault
Excess current has been
detected on the output side of
the welding power source.
Phase "W" on the primary
power supply side is not
connected.
The temperature of the pull-feed
motor has exceeded the
permissible range.
CAN communication fault.
10 Faults and troubleshooting
Measure
► Check that the contact pipe at the end of the torch is not
touching the component.
► Check all connecting cables for abnormalities
(e.g., short circuits).
The error message is canceled when the welding power
source is switched off.
► Check that the primary side voltage supply is free
of faults.
The error message is canceled when the welding power
source is switched off.
► Ensure that the wires are not stuck and that there are no
other abnormalities in the welding torch or wire feeder.
► Ensure that the welding torch or the supply hose is not
clogged.
The error message is canceled when the power switch is
turned off.
► Check whether the CAN communications line is firmly
plugged into the CAN communication connector's CN3
connection for the welding power source.
► Check whether the CAN communications line is firmly
connected to the CNCAN terminal of the AC servo wire
feeder controller.
The error message is canceled when the power switch is
turned off.