Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel iROB 501 Originalbetriebsanleitung Seite 122

Schweißstromquelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7 Operation
F45/F46/F47: Special end crater filling sequence
(Effective/Standard)
Enables the time for start and end crater current to be set. Turning on the F45 function allows the weld
start/end crater filling (set by the F46/F47 functions) to be executed.
When the function is activated, the LED above the <Operating mode> selection button blinks and the
F46/F47 functions are available. Internal function F46 is used to set the time for the weld start in the range
of 0.0 to 10.0 seconds.
The internal function F47 sets the time for the end crater filling in the range of 0.0 to 10.0 seconds.
Start signal
Gas flow
Output voltage
Wire feed speed
Welding current
Adjustable range
Default value
Storage option
Description
Adjustable range
Default value
Storage option
Description
Adjustable range
Default value
Storage option
Description
EN - 42
ON
Gas pre-flows
Idle voltage
Creep speed
Starting current
Start
Main welding parameter
parameter
Set time via F46
ON/OFF
OFF
Yes
F45: Sets the start and end crater filling parameters for a set period
of time.
OFF: inactive
ON: parameters from F46 and F47 are used
0 to 10 s
0 s
Yes
F46: Defines the time of the starting current.
(Active if F45 is set to ON.)
0 to 10 s
0 s
Yes
F47: Defines the end crater filling time. (Active if F45 is set to ON.)
®
®
iROB
501, iROB
401, iROB
OFF
Gas post flows
Backburn time
Welding current
End crater filling flow
End crater
filling
Set time via F47
®
301