7 Operation

7.5 Setting internal functions

Internal functions provide additional adjustment options for the welding and/or device parameters and can
be adjusted by the user according to requirements.
The internal functions are activated by setting or changing a value.

7.5.1 Making settings

7.5.2 Description of the internal functions

Some internal functions can be saved with the welding parameters. These are marked with "Yes" in the
Storage option row of the tables in the descriptions.
Tab. 13
No./function name
F1: No function
F2: Setting pulse details
F3: Switching the heat input display
F6: Setting the rise time
F7: Setting the decay time
F8: Setting the display hold time
F12: Setting the run-on time for the cooling water
pump (option)
F14/F15: Adjusting the start control
(time and current)
F16: Setting the wire creep
F17/F18: Setting the backburn time/backburn
voltage
F19: Setting the switching off of the alarm
F20: Setting the lower threshold value of the
mains voltage monitoring
F21: Activating the maximum capacity of
the cooling fan
F22: Deactivating the button tones
F23: Setting the time period until stand-by mode
F24: Setting the wire feed speed
F25–F28: Setting external outputs
F29–F32: Setting external inputs
EN - 34
F
Press and hold the <Function> button for 1 or more seconds.
1
In the left digital display, the function number blinks. The parameter stored for
the function number is displayed in the right digital display.
Use the <Parameter setting> knob to select the function number to
2
be edited.
F
Press the <Function> button.
3
The right digital display blinks.
Use the <Parameter setting> knob to set the desired value.
4
F
Press the <Function> button to return the display to its initial state. The left
5
digital display blinks.
F
Press and hold the <Function> button for 1 or more seconds.
6
The internal function has been set and the display returns to the initial state.
Overview of internal functions
®
®
iROB
501, iROB
401, iROB
Adjustable
Starting value
range
ON/OFF
OFF
ON/OFF
OFF
0 to 10 s
0 s
0 to10 s
0 s
0 to 60 s
20 s
20 to 60 min
20 min
−100 to +100%
0%
−1 to 1 m/min
0 m/min
−50 to 50 ms
0 ms
−9.9 to +9.9 V
0 V
ON/OFF
OFF
260 to 400 V
320 V
ON/OFF
OFF
ON/OFF
ON
0 to 10 min
0 min
ON/OFF
OFF
0/4
0
0 to 12
0
®
301