The Kendall SCD™ 700 series controller is intended for use in the electromagnetic environment specified below. The customer or the user of the Kendall
SCD™ 700 series should assure that it is used in such an environment.
Immunity test
Conducted RF
3 Vrms
IEC 61000-4-6
150 kHz to 80 MHz
Radiated RF
3 V/m
IEC 61000-4-3
80 MHz to 2.5 GHz
NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures,
objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and
FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF
transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Kendall SCD™ 700 series
controller is used exceeds the applicable RF compliance level above, the Kendall SCD™ 700 series should be observed to verify normal operation. If
abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the Kendall SCD™ 700 series controller.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Recommended separation distance between
Portable and mobile RF communications equipment and the Kendall SCD™ 700 series @ 3Vrms
The Kendall SCD™ 700 series controller is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The
customer or the user of the Kendall SCD™ 700 series can help prevent electromagnetic interference by maintaining a minimum distance between
portable and mobile RF communications equipment (transmitters) and the Kendall SCD™ 700 series controller as recommended below, according to
the maximum output power of the communications equipment.
Rated maximum output power
of transmitter W
0.01
0.1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using
the equation applicable to the frequency of the transmitter, where P is the maximum output rating of the transmitter in watts (W) according to the
transmitter manufacturer.
Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects
and people.
EN-29
Guidance and manufacturer's declaration - electromagnetic emissions
IEC 60601
Compliance
Test level
3 Vrms
3 V/m
Separation distance according to frequency of transmitter m
150 kHz to 80 MHz
3.5
d =
√P
v
1
0.12
0.37
1.17
3.69
11.67
Electromagnetic environment - guidance
Level
Portable and mobile RF communications equipment should be used no
closer to any part of the Kendall SCD™ 700 series controller, including
cables, than the recommended separation distance calculated from the
equation applicable to the frequency of the transmitter.
Recommended separation distance
3.5
d =
√P
v
1
3.5
d =
√P
E
1
7
d =
√P
E
1
where P is the maximum output power rating of the transmitter in
watts (W) according to the transmitter manufacturer and d is the
recommended separation distance in metres (m).
Field strengths from fixed RF transmitters, as determined by an
electromagnetic site survey,
each frequency range.
Interference may occur in the vicinity of equipment
marked with the following symbol:
80 MHz to 800 MHz
d =
80 MHz to 800 MHz
800 MHz to 2.5 GHz
a
should be less than the compliance level in
b
3.5
√P
E
1
0.12
0.37
1.17
3.69
11.67
Kendall SCD™ 700 Series
800 MHz to 2.5 GHz
7
d =
√P
E
1
0.23
0.74
2.33
7.38
23.33