Screwing in the adjusting sleeve
Positioning the complete system and mounting block
on the base plate
Calibrating the
Testing System
and Testing the
First Complete
System
Lightly securing the complete system with mounting
block
If the dowel pin does not glide into the adjusting sleeve or only does so with difficulty, the
complete system with mounting block must be readjusted
80
Remove the gas nozzle
5
To distinguish between centering sleeves
and adjusting sleeves, the adjusting slee-
ves are equipped with two additional cross
grooves.
Unscrew the appropriate adjusting
6
sleeve from the base plate of the Rob-
acta Complete System testing system
Screw the adjusting sleeve into the
7
torch neck of the complete system ins-
tead of the contact tip
The mounting block is designed for moun-
ting various robot shutoff boxes.
Disconnect the hosepack from the sys-
8
tem components
Secure the complete system to the
9
mounting block
Position the complete system with
10
mounting block on the base plate
Align the complete system with moun-
1
ting block with the testing unit at a mi-
nimum distance of 15 mm (0.59 inch)
from the adjusting sleeve
Lightly secure the mounting block
2
using a clamp
Test the complete system: Insert the
3
testing unit dowel pin into the adjusting
sleeve by pressing on the spring
-
The dowel pin must glide fully into
the adjusting sleeve with ease.
-
The dowel pin must glide out of the
adjusting sleeve with ease after
the spring is released due to the
spring force.