Calibrating The Testing System And Testing The First Torch Neck - Fronius Robacta series Bedienungsanleitung

Prüfvorrichtung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Positioning the torch neck and the torch neck holder
on the base plate
Calibrating the
Testing System
and Testing the
First Torch Neck
Lightly securing the torch neck holder
Securing the torch neck holder
Remove the gas nozzle
6
Place the torch neck in the torch neck
7
holder
Secure the torch neck using two union
8
nuts
Position the torch neck holder with
9
torch neck on the base plate
Align the torch neck holder with torch
1
neck in line with the testing unit at a mi-
nimum distance of 15 mm (0.59 inch)
from the contact tips
Lightly secure the torch neck holder
2
using a clamp
Check the position of the contact tips
3
by pressing on the testing unit dowel
pin
The test probes must fit perfectly into
the wire outlet openings on the contact
tips.
If the test probes do not fit perfectly into
the wire outlet openings of the contact
tips, the Twin complete system with
mounting block must be readjusted
Secure the mounting block by tigh-
4
tening the rest of the clamps in a diago-
nal pattern
Check the position of the contact tips
5
by pressing on the testing unit dowel
pin
-
The torch neck is okay if the test
probes fit perfectly into the wire
outlet openings on the contact
tips.
-
In the case of dimension devia-
tions, please send the torch neck
to Fronius for repairs.
If applicable, test all other torch necks
6
of identical construction as described
below
95