Replacing a Dual Rotating Gobo Module in Slot 2

Refer to Figure 5-8 for Steps 1–4 in this section.
1. Remove the bezel as shown in Figure 5-1 on page 5-1, and, with the lens pointed
up, rotate the fixture so the tilt belt (A) is on your right. Locate the Dual Rotating
Gobo Module in Slot 2 (nearest the lens) and gently push the module toward the
lens until the linear slide (B) reaches its limit.
2. Detach the IDC connector (C) from the driver board.
3. Loosen the two captive screws on the module (D) and pull it straight out of the
unit.
4. Slide the new module into the unit positioning the Gobo wheels on either side of
the Gobo wheel in Slot 3 on the opposite side of the fixture. Use the top (toward
the lens) channel guides (E) and the aligning pins (F) and to orient it properly

Figure 5-8 Installing/Removing Slot 2 Module.

5. Tighten the captive screws and reattach the IDC connector.
6. Reattach the bezel guiding it into the bezel channel on each yoke arm and
retighten captive bezel screws as shown in Figure 5-1 on page 5-1.
7. Place the old module in the new unit's anti-static bag for return. Include the
Return Material Authorization number (RMA#) obtained from your dealer or
point of purchase along with a written explanation of the problem or
malfunction.