5. If CURRENT TEMPERATURE, MAXIMUM TEMPERATURE, or MINIMUM TEMPERATURE
is selected, use the up and down arrows on the Navigation button to view the
temperature on the Topbox and Head sensors.
6. When TEMPERATURE RESET is selected, NO is displayed as a safe setting. Use the
up and down arrows on the Navigation button to scroll to YES. Press the Enter
button and hold for 5 seconds to reset all sensors to the CURRENT TEMPERATURE
value.

Fixture Hours

Use this option to view the fixture operation time in hours and minutes.

Fixture Hours Reset

Use this option to reset the fixture operation time to Zero.
To access the FIXTURE HOURS RESET option:
1. Press the Menu button to unlock the menu system or to move back up the system
to the top level menus.
2. Use the left and right arrows on the Navigation button to scroll to the
INFORMATION MENU and press the Enter button to select.
3. Use the left and right arrows on the Navigation button to scroll to the
FIXTURE HOURS RESET option and press the Enter button to select.
4. Use the up and down arrows on the Navigation button to scroll to YES. Press and
hold the Enter button down for 5 seconds to select.

Lamp Hours

Use this option to view the lamp operation time in hours and minutes.

Lamp Strikes

Use this option to view the total number of lamp strikes.

Lamp HR/Strike Reset

After installing a new lamp the Lamp hours and Lamp strike sensors must be reset to
0 before the Lamp will strike.
To access the LAMP HR/STRIKE RESET option:
1. Press the Menu button to unlock the menu system or to move back up the system
to the top level menus.
2. Use the left and right arrows on the Navigation button to scroll to the
INFORMATION MENU and press the Enter button to select.