Note: The last valid Start channel for an x.SpotXtreme fixture is based on the
channel range required by fixture's module configuration. The last valid start
channel for a standard configuration x.SpotXtreme fixture is 475 (512–38+1).
5. Press the Enter button to accept the new DMX Start channel. The display will
stop flashing when a new option is entered. The new option will not be stored
until the Enter button is pressed.

Shutting Down the Fixture

The x.SpotXtreme fixture automatically shuts down in the event of DMX data loss. A
DMX controller can shut down the fixture remotely with the Shutdown option in the
Control Channel, see "Appendix A: DMX Protocol" for DMX tables.
Note: Before shutting down the fixture, set the Focus parameter to 65%. This
balances the head on shutdown for easier handling and transporting.