Display Error Messages
8 Character
16 Character Error
Error Message
Message
FROST HOMING
EDGEFRST
EDGE NOT FOUND
MODULE SLOT 1
SLOT 1 ID
CONFIG CHANGE
MODULE SLOT 2
SLOT 2 ID
CONFIG CHANGE
MODULE SLOT 3
SLOT 3 ID
CONFIG CHANGE
Location
Focus/Frost/Zoom module 2
phase board, motor M1, sensor
S3
Module in Slot 1
Module in Slot 2
Module in Slot 3
Problem/Procedure
For replacement parts, see "Contacting High End Systems®" on page ii
Frost not homing correctly:
1. Check Frost sensor connection at sensor and board.
2. Check Frost motor wire connection at motor and board.
3. Check for wire damage.
4. Verify board functioning by substituting with another 2-phase board
from the fixture, see "Replacing a Driver Board" on page 5-6.
5. Check that Frost sensor tab is installed and operating.
6. Check that Frost gear set screw is tight.
7. Check that Frost gear is aligned with frost flag teeth.
8. Replace motor.
CPU did not find module:
1. Check that module is assigned to slot ID, see "Module Configuration
Menu" on page 3-20.
2. Check that module is plugged into head harness.
3. Check head harness, tilt harness, pan harness, top box harness for
connection and damage, see "Wire Harness Connections" on page
6-9.
4. Check if motor power supply output fuse is blown, see "Replacing
Fuses" on page 5-2.