Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Operation And Maintenance - MICRO-EPSILON wireSENSOR WDS series Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation

5.
For draw wire sensors with potentiometer output (P) there are no adjustment and setting elements.
Draw wire sensors with voltage output (U) or current output (I) are equipped with integrated electronics with
setting potentiometers (trimmers) for zero and gain.
The access holes for the trimmers are located in the housing cover.
With the zero trimmer the zero point can be shifted by ±20 % of the range with voltage output (±18 % with
current output).
With the gain trimmer the signal span (sensitivity) is adjusted by ±20 % with voltage output (±15 % with cur-
rent output). For draw wire sensors with encoder output (E,A) there are no adjustment and setting elements.
Standard setting:
U-output:
I-output:
6.
Imperfect wire guiding can lead to increased wear and premature defects.
The warranty and all liability claims are null and void if the device is manipulated by unauthorized persons.
Repairs are to be made exclusively by MICRO-EPSILON, see Chap.
wireSENSOR, WDS P60/P96/P115
Operation
0 - 10 Volt
4 - 20 mA

Operation and Maintenance

Do not grease or oil the measuring wire, the wire drum, the spring motor and the potentiometer.
Observe the notes on wire guiding, see Chap. 4.3, during operation.
8.