Installation and Mounting
Input +
Ground
Signal
Fig. 20 Model with potentiometer output
i
Using them as a variable resistor, destroys the element.
Draw wire sensors with voltage or current output are connected by the 8-pin built-in plug according to the pin
assignment, see
An 8-pin cable socket for the user-side assembly of your own connecting cable is part of the delivery scope
of the standard sensors.
Note when assembling (Requirements of power and output cables to satisfy the EMC regulations):
- Recommended conductor cross-section 0.14 mm
- Maximum cable diameter 8 mm / 0.3 inch.
The EMC regulations are only satisfied under these basic conditions.
A pre-assembled connecting cable PC3/8 is available as an accessory, see Chap.
wireSENSOR, WDS P60/P96/P115
1
100 %
2
3
0 %
Use the potentiometer only as a voltage divider, not as variable series resistor!
Ensure that the maximum current through the viper is limited.
Fig.
19, see
Fig.
Use a screened cable.
Earth screen on electronics side.
21, see
Fig.
22.
(up to 9 m/30 ft cable length)
2
A
2.