Functional Principle, Technical Data
Models with current output (2-wire) WDS - .... - Pxx - SR - I
Electrical data
Supply voltage:
Current consumption:
Output current:
Load:
Temperature coefficient:
Output noise:
Adjustment ranges
Zero:
Sensitivity:
EMC:
wireSENSOR, WDS P60/P96/P115
14 to 27 VDC non stabilized (measured on the input terminal of the sensor)
35 mA max.
4 to 20 mA
< 600 Ohm
±0.01 % FSO/K (±0.005 % FSO/°F)
< 1.6 µA
eff
±18 % FSO
±15 %
acc. DIN EN 61326-1: 2006-10 and DIN EN 61326-2-3: 2007-05
Page 65