Herunterladen Inhalt Inhalt Diese Seite drucken

Checks After Repairs, Safety Inspection; Inspection After Repair; Carrying Out A Safety Inspection - Fronius Robacta Drive CMT Serviceanleitung

Roboter-schlauchpaket
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Checks after repairs, safety inspection

Inspection after
Insulation test
repair
Test insulation using
Test voltage
Resistance
a)
b)
Function test
Check Robacta Drive CMT function after repairs:
-
-
Carrying out a
A safety inspection must be carried out according to the relevant national and local
safety inspection
regulations:
-
-
-
-
The latest version of the work instructions "Safety inspection of welding systems during
repair and maintenance" can be found as a pdf file in the online TechGuide (http://
www.fronius.com/techguide) under "General" and "Basics".
the Metriso 5000 insulation testing device.
1000 V
> 6 MOhm
Between torch neck coupling and motor housing
Between motor shaft and motor housing
according to the PP-QW-3083 (Robacta Drive) test schedule no. 4
according to „Error search tree" section
after any changes are made
after any additional parts are installed and after any conversions
after repair, care and maintenance
at least once every twelve months