7.3
Installation in water tank mode
1
Fig. 3
Rear view with rotary valve and water connection nozzle
1
Rotary valve in water tank mode position
1.
Move the rotary valve (1, Fig. 3) into the tank mode position. The valve
points towards the water connection nozzle (2, Fig. 3).
2.
Activate the tank mode via the menu (see Chapter 10.4.5, „Tank Mode").
7.4
Installation with mains water connection
CAUTION
Damage due to improper installation
If the machine is not connected up properly to the water supply, this could
damage the water lines and the machine.
• In case of any doubt, have a specialist install the machine.
• The water pressure must not exceed 2 bar.
• Only use the water connection hose included in the scope of delivery. Do
not re-use old hoses.
For use with the mains water connection, the machine must be connected up
to the water supply. The machine must be connected up to the water supply
as per the instructions in this manual. Applicable laws and regulations must
be observed when installing the machine.
7.4.1
Additional requirements at the installation site
There must be a drinking water connection with an operating pressure of at
least 1 bar and at most 2 bar at the installation site.
DRIVE_BA_V3.0
2
Water connection nozzle
2
EN - 115