7.4.2

H2O Error!

If the pump is switched on and the coolant flow is still insufficient after 20
seconds, the acoustic alarm sounds continuously and the associated LED
flashes. The pump is switched off automatically. Please check the water circuit.
Ensure that the flow and return connections of the water-cooled TIG torch are
properly attached and the water-carrying hoses of the TIG torch are not kinked or
blocked. When longer hose packages are being used, it can take more than 20
seconds for an empty hose package to fill. In this case, please select On or Auto
mode again.
The acoustic alarm can be switched off by pressing the pushbutton.
7.5

Water cooling unit maintenance

The maintenance intervals are a recommendation from REHM for normal
standard requirements (e.g. single-shift operation, use in clean and dry
environment). The exact intervals are defined by your safety officer.
7.5.1

Maintenance table

Activity
Cleaning the inside of the device
Blow out interior of device with clean, dry air
Coolant monitoring
Replace coolant
Function check of safety equipment by
operators
Visual inspection of system, particularly
torch hoses
Have connecting lines and torch hoses
inspected by experts, log inspection in
provided inspection book
Have entire water system inspected by
experts, log inspection in provided inspection
book
Water cooling
Interval
depending on the usage conditions,
but at least twice per annum
daily
annually
daily
daily
every six months
annually