Functional description
Special parameter factory settings SP CLr
When CLr is selected, the digital display starts to flash. All parameters
are set to the factory settings. Programs 1 to 99 and the special
parameters remain available.
Welding parameters
Gas pre-flow time
Ignition current
Starting current
Current upslope time
Current I1
Current I2
Pulse time t1
Pulse time t2
Current downslope time
End crater current
Gas post-flow time
AC frequency*
AC balance*
Ignition
Operating mode
Polarity*
Electrode current I1
Hot-Start current
Arc Force current
Pulse type
Pulse frequency
* not with DC units
Factory settings
0.1 seconds
50%
50%
0.1 seconds
100 A
80 A
0.3 seconds
0.3 seconds
0.1 seconds
20%
5.0 seconds
Automatic
- 65%
HF on
2-step
DC Minus
150 A
70%
70%
Pulse off
500 Hz