Herunterladen Inhalt Inhalt Diese Seite drucken

Selecting Programs P1 And P2 Using The Up/Down Torch; Anti-Stick Function - REHM INVERTIG.PRO COMPACT 240 DC Betriebsanleitung

Wig-schutzgas-schweißanlagen
Vorschau ausblenden Andere Handbücher für INVERTIG.PRO COMPACT 240 DC:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Functional description
3.14.3 Selecting programs P1 and P2 using the Up/Down
torch
For this purpose special parameter SP2 must be set to "2" (see Chapter 3.13
Special parameters).
GB
The Up/Down torch can be used to select the programs P1 and P2 before
welding. When program P1 or program P2 is activated, the appropriate quick set
button lights up [30].

3.14.4 Anti-stick function

If a permanent short-circuit occurs when MMA welding, after approximately 0.3
seconds, the anti-stick function starts up. This limits the current to approximately
20 A. This ensures that the permanent short circuit can be resolved by pulling
gently the electrode and prevents electrode overheats.
35

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis