No function at the REHM operating panel
The digital display instrument shows no display and none of the LEDs are lit
Cause:
No mains power (possibly due to mains fuse)
Defect in the mains power cord or connector
Current rise time and current down slope time are at "0.0" and cannot be changed
Cause:
Foot remote control is attached
Current rise time and current down slope time
are not being met
Cause:
Start current set to 100 %
End crater current set to 100%
4-step cannot be set
Cause:
Foot remote control is attached
Balance and frequency cannot be selected
Cause:
Polarity is not "  "
52
8.

Faults TIG welding machine

8.1

Safety notes

Warning!
In the event of a fault occurring which may endanger persons, machinery
or the surrounding area, deactivate the unit immediately and ensure that it
cannot be reactivated.
Only restart the unit when the cause of the fault has been eliminated and
no further risk is posed to people, machinery and/or surrounding area,
Faults should only be eliminated by qualified personnel and all safety notes
should be observed.
The unit must be released for use by qualified personnel before being
restarted.
8.2

Table of faults

Solution:
Check mains voltage
Check
Solution:
Times are controlled by remote.
Remove remote control.
Solution:
Lower start current value
Lower end crater current value
Solution:
Remove remote control.
Solution:
Can only be set in alternating current area