Cause:
Electrode and work piece do not reach
working temperature.
WIG electrode has no tip.
No suitable WIG electrode
Wrong polarity
Arc has a strange colour during WIG welding
Cause:
No/too little/wrong shielding gas
WIG electrode is dirty.
WIG electrode burns off
Cause:
No shielding gas
Current load too high
Connectors for torch and grounding cable swapped. Connect the correct way round.
Electrode welding selected.
Error
Error
number
1
Phase failure
2
Overvoltage
3
Undervoltage
21
WIG torch in
electrode
operation
> 51
Contact service.
28
7.3
Error messages
Cause
1. At least one phase of main
supply voltage failed.
Mains voltage produced
overvoltage.
> 480 V
Mains voltage produced
undervoltage.
< 320 V
Electrode operation active
with a WIG torch
connected.
Analysis of causes can only be carried out by a service technician.
Solution:
Use thinner electrode.
Sharpen WIG electrode
Change electrode.
Change polarity.
Solution:
Check.
Sharpen.
Solution:
Check.
Use thicker WIG electrode.
Select WIG welding
2. Check main fuse, cables and
connectors
Check mains voltage.
Check mains voltage.
Remove WIG torch.
Switch to WIG operation.
Faults
Solution