Herunterladen Diese Seite drucken

ECOLAB Versatronic Kurz- Betriebsanleitung Seite 118

Vorschau ausblenden Andere Handbücher für Versatronic:

Werbung

Unit menu
Configuration point Selection/configuration
KT X bleeding
monitoring y/n
KT X time bleeding
monitoring
KT X enable monitoring
y/n
KT X time enable
monitoring
KT X cal.timer y/n
KT X calibr.interv.
KT X source temp.
KT X temp. signal type PT100
KT X Temp. connection
type
KT X S← Reset period
for fresh water quantity
(C1 only)*
KT X S← Reset
threshold Fresh water
quantity (C1 only)*
417102279 Rev. 4-07.2023
Inactive
active
Number field
Range: - 999 to 999 s
Inactive
active
Number field
Range: - 999 to 999 s
Inactive
active
0–9999 days
*IN4 temperature input 1
* IN5 temperature input 2
...
IN11 Universal input 2
uncomp.*IN11
Universal input 2 comp.
IN12 Universal input. 3
uncomp.
* IN12 Universal input. 3
comp.
* = please only select the marked points!
PT1000
2-wire
3-wire
Off
Hourly
Daily
Weekly
Monthly
Yearly
Unlimited
0–99999 l
56
Explanation
Activation of bleeding
monitoring
(If the bleeding process is not
completed by a specified time
after the start of bleeding, the
display shows "bleed alarm".)
Set time for bleeding
monitoring
Activation of enable monitoring
(If the enable signal is not
issued when a biocide dosage
is pending, the system waits
for a specified period to see
if the signal is received. If
no enable signal is received
after the time period lapses,
an "enable alarm" signal is
output.)
Set time for enable monitoring 0 s
Activation of calibration timer
Determine calibration interval
The calibration interval is the
time after which a calibration
reminder is displayed on
Ä Chapter
the display (see
9.1.3 'Display elements'
on page 43 ). After performing
a calibration, the calibration
reminder is deleted on the
display.
Determine the source for the
temperature display and for
temperature compensation of
the respective channel.
With this selection, it
is possible to use the
temperature signal of another
channel for the display and
temperature compensation of
this channel.
Selection of type of
temperature sensor and thus
the type of temperature signal
Connection type of
temperature probe
Select the time period after
which the count input for the
fresh water quantity is to be
reset to zero.
If "unlimited" is selected for
KT X S← Reset time, a
numerical value in litres can be
entered here above which the
count input for the fresh water
quantity is reset to zero.
Default
Inactive
0 s
Inactive
Inactive
10 days
Channel 1: IN4
Channel 2: IN5
Channel 3: IN11
comp.
Channel 4: IN12
comp.
PT1000
3-wire
Unlimited
99999 l

Werbung

loading