Maintenance
9.1

Replacing the fan

Construction types
A to C
9-2
The fan is designed for an operating time of L
ambient temperature of T
to maintain the availability of the unit.
The fan is located on the bottom of the unit.
Replace the fan as follows:
♦ Undo the two M4x49 Torx screws
♦ Pull out the protective cover together with the fan from underneath
♦ Withdraw fan connector X20
♦ Install the fan in reverse sequence.
Protective cover
M4 x 49 / Torx T20
and spring washer
Fig. 9-1
Cover and fan for housing size A to C
10
= 40 °C. It should be replaced in good time
u
X20
M4 x 49
Torx T20
and
spring washer
Fan E1
Operating Instructions
10.98
≥ 35 000 hours at an
6SE7087-6JD50
Siemens AG
SIMOVERT MASTERDRIVES