Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SIMOVERT MASTERDRIVES Motion Control Betriebsanleitung Seite 171

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10.99
Setpoint and command source
Terminal strip and motorized potentiometer
Type of control
V/f control
Ref speed
Norm.
P353
Accel Time
Decel Time
P462.1
P464.1
Analog output
AnaOut Offset
+/- 10 V
P644.1
AA
-X101/11
A
D
-X101/12
Type of encoder:
Without encoder
Siemens AG
6SE7087-6JD50
SIMOVERT MASTERDRIVES
-X101/1
P24
-X101/2
M24
1 = Operation
-X101/3
0 = Fault
-X101/4
1 = Raise MOP
-X101/5
1 = Lower MOP
-X101/6
1-Edge = Acknowledge
-X101/7
-X101/8
1 = ON 0 = OFF1
r003 Output Volts
r004 Output Amps
r006 DC Bus Volts
Ref Freq
n(max, FWD speed)
P352
P452.1
Norm.
n(max, REV speed)
P453.1
AnaOut Smooth
AnaOut Scale
P642.1
P643.1
y
x
x
y[V]=
P643.1
100 %
Operating Instructions
MOP Accel Time
MOP Decel Time
P431
P432
MOP(max)
MOPi(min)
Conf MOP
P425
00x0 = ... Without storing after OFF
00x1 = ... Storing after OFF
Volts Curve1
P327
U
.3 .4
.2
.1
Boost
P325
.1 .2 .3 .4
f
Freq Curve1
P326
Disp Freq Conn
r043.2
(=Frequency actual value)
Parameterization
P421
P422
Motor
3~
Motor
encoder
8-19