Assembly and Connection

The assembly instructions relate to the 1-door version and is also valid for the 2-door
version with the exception of the canister support.
The
DG 3
is designed for the connection of the product reservoir on the right-hand side.
If required, the product reservoir can also be placed on the left-hand side of the housing.
This involves moving the suction lance and the outlet for the power cable to the left-hand
side of the housing.
The following connection and installation instructions constitute the recommended
NOTE
procedure. However, the ambient conditions determine the actual assembly and installation
methods. It is important to pay attention to conditions at the site of use.
7.1

Installation

To ascertain necessary drilling spacing, please refer to the descriptions in chapter
NOTE
"Connection Diagram / Dimensions".
7.1.1

Wall mounting of the DG3 with 1 door

The scope of delivery contains a mounting kit with rawl plugs, shims, and fastening screws
for installing the
417102242_DG_3
DG
3. If required, use special plugs and screws to secure the device.
- 71 -
15.1
Item
Description
1
Rawl plugs (4 x)
2
Rear panel of housing
3
Screws (4 x)
4
Rawl plugs (2 x)
5
Screws (2 x)
6
Console
7
Cover
8
Stop screws (3 x)
Fig. 7.1
Wall mounting of the DG3 with 1 door