Herunterladen Inhalt Inhalt Diese Seite drucken

Emergency Stop Impact Switch; Lockable Main Switch - Optimum OPTImill BF 46TC Betriebsanleitung

Bohr- fräsmaschine
Vorschau ausblenden Andere Handbücher für OPTImill BF 46TC:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OPTIMUM
M A S C H I N E N - G E R M A N Y
WARNING!
If you bypass, remove or deactivate a safety device in any other way, you are
endangering yourself and other staff working with the drilling-milling machine. The
possible consequences are
injuries due to components or parts of components flying off at high speed,
contact with rotating parts,
fatal electrocution.
The drilling-milling machine includes the following safety devices:
an EMERGENY-STOP button,
a protective cover on the drilling / milling head.
a separating protective device on the milling spindle,
WARNING!
The separating protective equipment which is made available and delivered together
with the machine is designed to reduce the risk of workpieces or fractions of them which
being expelled, but not to remove them completely. Always work carefully and observe
the limit values of your chipping process.

1.8.1 EMERGENCY STOP impact switch

The EMERGENCY STOP push button
switches off the drilling-milling machine.
ATTENTION!
The EMERGENCY-STOP push button stops the machine the moment it is activated.
Activate the emergency stop impact switch only in case of danger! If this push button is
actuated in order to switch off the drilling-milling machine in the standard operation the
tool or workpiece might get damaged.
After having actuated the EMERGENCY STOP, turn the knob of the particular push button to
the right in order to restart the machine.

1.8.2 Lockable main switch

In the position " 0 " the lockable main
switch can be secured against accidental
or non-authorized switching-on by means
of a padlock.
When the main switch is switched-off, the
current supply is interrupted.
Except for the areas marked by the picto-
gram in the margin.
GB
BF46V | BF46TC
Page 64
EMERGENCY-
STOP
Img.1-2:
Main switch
Img.1-3:
Original operating instructions
EMERGENCY STOP impact switch
Main switch
Version 1.1.3 dated 2014-4-8