Herunterladen Inhalt Inhalt Diese Seite drucken

RayTek MI3 Betriebsanleitung Seite 125

Vorschau ausblenden Andere Handbücher für MI3:
Inhaltsverzeichnis

Werbung

Description
Char
Head identification
HI
Top temperature value
H1O
of output 1
(H)
Top temperature value
H2O
of output 2
Top temperature
H3O
value of output 3
2
Top temperature
H4O
value of output 4
3
Laser Control
HL
4
Head serial number
HN
Head special
HS
Head Firmware Revision HV
Restore Head Factory
HXF
defaults
Head ambient
I
Switch panel lock
J
Relay alarm output
K
control
depreciated for MI3 (use
the commands KB and
KH instead of)
Relay alarm output
KB
control
Relay alarm output
KH
control
Bottom temperature
L1O
value of output 1
(L)
Bottom temperature
L2O
value of output 2
Temperature is over setpoint
Self factory default executed
for MI3COMM only
1
for MI3MCOMMA only
2
for MI3MCOMMA only
3
for MI3100 heads only
4
for MI3COMM only
5
MI3
Format
P B S N Legal Values
?nHI
string
float
1
float
float
float
nHL
integer
?nHN
integer
?nHS string
?nHV
nHXF
?nI
 
float
X
K
integer
KB
integer
nKH
integer
float
5
float
BIT11
(ab Rev. 2.20, not for Profibus communication boxes)
BIT12
(ab Rev. 2.20, not for Profibus communication boxes)
Rev. G1 Nov 2016
ASCII Programmierung
e.g. !7HIMIXLTS22
(
)
  H1O= –40.0
or H= –40.0
  H2O= –40.0
  H3O= –40.0
  H4O= –40.0
  0=off, 1=on, 2=flash,
3=external
e.g. !nHN98123
e.g. !99HSRAY
e.g. 1.01
answer !nI=0099.9
  L = locked
U = unlocked
0 = off
1 = on
2 = Target norm. open
3 = Target norm. closed
4 = Intern norm. open
5 = Intern norm. closed
0 = off
1 = on
2 = norm. open
3 = norm. closed
0 = off
1 = target temp.
2 = head ambient
  L1O= –40.0 or
L= –40.0
  L2O= –40.0
Factory default Head /
Box
set at production H
500°C
B
500°C
B
500°C
500°C
0
H
set at production H
Set at
H
production
Set in FW
H
H
H
unlocked
B
2
H
2
B
1
H
0°C
B
0°C
B
125