h) Activation time for outputs #1, #2 and #3

By default, outputs #1, #2 and #3 are activated for 1 second when a valid user or visitor code
is entered.
The activation duration can be set from 1 - 999 seconds (i.e. more than 16 minutes).
Each output can also be used in "toggle" mode. This allows you to permanently enable and
then disable the corresponding output. Use this mode to control (arm/disarm) an alarm system.
In toggle mode, the output is activated until you disable it by entering a user code.
We recommend that you only use toggle mode in combination with an alarm system
or a fail-safe door opener.
Fail-safe door openers release the latch when the power is removed (non-standard
door opener type, used for emergency exit doors so that the door opens in the event
of a power cut).
Fail-secure door openers (releases the latch when power is supplied; used for house
doors) may overheat when the output is permanently enabled.
Activating output #1, #2 or #3 for a limited period:
When you enter a valid user code (or visitor code), the corresponding output will remain acti-
vated for the preset duration. The output will be disabled when the set time has elapsed. Use this
mode if you want the door opener to keep the door open for a few seconds.
Follow the steps below:
• The code lock must be in programming mode (see section 12. a) for details).
• Enter the programming code for corresponding output:
Activate output #1 for a limited period
Activate output #2 for a limited period
Activate output #3 for a limited period
• Enter the duration (in secs) for which the output should remain activated:
.....
• Press the
button to confirm your entry. The code lock will beep twice and the "MAINS"
LED will flash two times to indicate that the setting has been saved.
94
Activation duration in seconds (1.....999)