Herunterladen Inhalt Inhalt Diese Seite drucken

Renkforce 1582598 Bedienungsanleitung Seite 88

3-kanal-multifunktions-codeschloss
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Function in normal mode:
To activate output #1, #2 or #3, ensure that the code lock is in normal mode (not programming
mode), enter the user code, and then press the
See section 12. h) for instructions on how to set the activation duration for the three outputs.
You do not need to press the
tion 12. m). The code lock activates the corresponding output when the correct user
code is entered.
When "Auto entry" mode is enabled, each code must be the same length (e.g. if the
master code is 5 digits, the user codes must also be 5 digits).
Deleting user codes:
User codes can be deleted if you want to prevent a user from accessing the door (e.g. when an
employee changes departments or leaves the company).
You can also overwrite existing user codes with a new code.
Follow the steps below:
• The code lock must be in programming mode (see section 12. a) for details).
• Enter the programming code for output #1, #2 or #3:
Output #1
Output #2
Output #3
• Enter a memory slot number.
.....
.....
• Press the
button to confirm your entry. The code lock will beep twice and the "MAINS"
LED will flash two times to indicate that the user code has been deleted.
88
Output #1 is activated
Output #2 is activated
Output #3 is activated
button when "Auto entry" mode is enabled (see sec-
100 memory slots for output #1
10 memory slots for output #2 or #3
button.