e) User codes
The code lock can store up to 120 user codes. You can store up to 100 user codes for output #1
and 10 user codes each for outputs #2 and #3.
The following section provides an introduction on how to use codes to enable the code lock
outputs (e.g. to release a door opener), including a number of examples.
We recommend that you create a table to record all access data (including code
numbers, user codes and user names for outputs #1, #2 or #3). This will help you to
monitor registered users and access permissions.
It will also make it easier to delete users and the corresponding user codes.
Saving a user code:
• The code lock must be in programming mode (see section 12. a) for details).
• Enter the programming code for output #1, #2 or #3:
Output #1
Output #2
Output #3
• Enter a memory slot number.
.....
.....
• Enter the desired 4- 8 digit user code.
Important!
In "Auto entry" mode (see section 12. m), all codes must be the same length (e.g. if
the master code is 5 digits, the user codes must also be 5 digits).
• Press the
button to confirm your entry. The code lock will beep twice and the "MAINS"
LED will flash two times to indicate that the setting has been saved.
• You can now create another user (enter the program code for one of the three outputs).
• When you have finished adding all users, press
12. a) for details).
86
100 memory slots for output #1
10 memory slots for output #2 or #3
to exit programming mode (see section