Signal Contact

73.1.2 signal-contact monitor link-failure

Sets the monitoring of the network connection(s).
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor link-failure
Parameter Value
signal contact no.
P-1
no signal-contact monitor link-failure
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor link-failure

73.1.3 signal-contact monitor module-removal

Sets the monitoring of the module removal.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor module-removal
Parameter Value
signal contact no.
P-1
no signal-contact monitor module-removal
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor module-remo-