Precision Time Protocol (PTP)

63.1.17ptp v2-boundary-clock utc-offset

Configure the current UTC offset (TAI - UTC) in seconds.
Mode: Global Config Mode
Privilege Level: Administrator
Format: ptp v2-boundary-clock utc-offset <P-1>
Parameter Value
-32768..32767
P-1

63.1.18ptp v2-boundary-clock utc-offset-valid

Configure the UTC offset valid flag
Mode: Global Config Mode
Privilege Level: Administrator
Format: ptp v2-boundary-clock utc-offset-valid <P-1>
Parameter Value
true
P-1
false
no ptp v2-boundary-clock utc-offset-valid
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no ptp v2-boundary-clock utc-offset-valid <P-
1>