Herunterladen Inhalt Inhalt Diese Seite drucken

Signal-Contact Monitor Link-Failure; Signal-Contact Monitor Envm-Not-In-Sync - Hirschmann Hios-2S Rspl Referenzhandbuch

Command line interface (cli) (rail switch power lite)
Inhaltsverzeichnis
Signal Contact

50.1.2 signal-contact monitor link-failure

Sets the monitoring of the network connection(s).
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor link-failure
Parameter Value
signal contact no.
P-1
no signal-contact monitor link-failure
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor link-failure

50.1.3 signal-contact monitor envm-not-in-sync

Sets the monitoring whether the external non-volatile memory device\nis in
sync with the running configuration.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor envm-not-in-sync
Parameter Value
signal contact no.
P-1
no signal-contact monitor envm-not-in-sync
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor envm-not-in-
sync
RM CLI HiOS-2S RSPL
Release 5.0 05/2015
Meaning
Meaning
50.1 signal-contact
543
Inhaltsverzeichnis
loading

Inhaltsverzeichnis