Signal Contact

73.1 signal-contact

Configure the signal contact settings.

73.1.1 signal-contact mode

Configure the Signal Contact mode setting.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> mode <P-2>
Parameter Value
signal contact no.
P-1
manual
P-2
monitor
device-status
security-status
dev-sec-status
792
Meaning
The signal contact's status is determined by
the\nassociated manual setting (subcommand
'state').
The signal contact's status is determined by
the\nassociated monitor settings.
The signal contact's status is determined by
the\ndevice status.
The signal contact's status is determined by
the\nsecurity status.
The signal contact's status is determined by
the\ndevice status and security status.