Herunterladen Diese Seite drucken

Profinet; Profinet Dcp-Mode - Hirschmann HiOS-2A GRS1040 Referenzhandbuch

Greyhound switch
Vorschau ausblenden Andere Handbücher für HiOS-2A GRS1040:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Profinet IO

62.2 profinet

Configures the PROFINET functionality on this device.

62.2.1 profinet dcp-mode

Sets the PROFINET DCP mode on an interface.
Mode: Interface Range Mode
Privilege Level: Operator
Format: profinet dcp-mode <P-1>
Parameter Value
none
P-1
ingress
egress
both
RM CLI HiOS-2A GRS1040
Release 6.1 09/2016
Meaning
Sets the PROFINET DCP mode on an interface
to none (neither ingress or egress). The
agent does not respond to frames received on
this interface. The interface does not for-
ward frames received on other interfaces.
Sets the PROFINET DCP mode on an interface
to ingress only. The agent responds to fra-
mes received on this interface. The inter-
face does not forward frames received on
other interfaces.
Sets the PROFINET DCP mode on an interface
to egress only. The agent does not respond
to frames received on this interface. The
interface forwards frames received on other
interfaces.
Sets the PROFINET DCP mode on an interface
to both (ingress and egress). The agent res-
ponds to frames received on this interface.
The interface forwards frames received on
other interfaces.
62.2 profinet
701

Werbung

Kapitel

loading