Precision Time Protocol (PTP)
Parameter Value
v2-boundary-clock
P-1
v2-transparent-clock

63.1.3 ptp sync-lower-bound

Configure the lower bound for the PTP clock synchronization status \n(unit:
nanoseconds). If the absolute value of the offset \nto the master clock is
smaller than the lower bound, \nthe clock's status is set to synchronized
(true).
Mode: Global Config Mode
Privilege Level: Administrator
Format: ptp sync-lower-bound <P-1>
Parameter Value
1..999999999
P-1

63.1.4 ptp sync-upper-bound

Configure the upper bound for the PTP clock synchronization status \n(unit:
nanoseconds). If the absolute value of the offset \nto the master clock is big-
ger than the upper bound, \nthe clock's status is set to unsynchronized
(false).
Mode: Global Config Mode
Privilege Level: Administrator
Format: ptp sync-upper-bound <P-1>
Parameter Value
31..1000000000
P-1