Signal Contact

73.1.6 signal-contact monitor temperature

Sets the monitoring of the device temperature.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor temperature
Parameter Value
signal contact no.
P-1
no signal-contact monitor temperature
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor temperature

73.1.7 signal-contact monitor ring-redundancy

Sets the monitoring of the ring-redundancy.
Mode: Global Config Mode
Privilege Level: Administrator
Format: signal-contact <P-1> monitor ring-redundancy
Parameter Value
signal contact no.
P-1
no signal-contact monitor ring-redundancy
Disable the option
Mode: Global Config Mode
Privilege Level: Administrator
Format: no signal-contact <P-1> monitor ring-redun-
dancy