Logging

48.1.20logging email severity urgent

Urgent severity level
Mode: Global Config Mode
Privilege Level: Administrator
Format: logging email severity urgent <P-1>
Parameter Value
emergency
P-1
alert
critical
error
warning
notice
informational
debug
0
1
2
3
4
5
6
7

48.1.21logging email severity non-urgent

Non-urgent severity level
Mode: Global Config Mode
Privilege Level: Administrator
Format: logging email severity non-urgent <P-1>
584
Meaning
System is unusable. System failure has
occurred.
Action must be taken immediately. Unrecover-
able failure of a component. System failure
likely.
Recoverable failure of a component that may
lead to system failure.
Error conditions. Recoverable failure of a
component.
Minor failure, e.g. misconfiguration of a
component.
Normal but significant conditions.
Informational messages.
Debug-level messages.
Same as emergency
Same as alert
Same as critical
Same as error
Same as warning
Same as notice
Same as informational
Same as debug