Selftest
70.1 selftest
Configure the selftest settings.
70.1.1 selftest action
Configure the action that a selftest component should take.
Mode: Global Config Mode
Privilege Level: Administrator
Format: selftest action <P-1> <P-2>
Parameter Value
task
P-1
resource
software
hardware
log-only
P-2
send-trap
reboot
70.1.2 selftest ramtest
Enable or disable the RAM selftest on cold start of the device. When disabled
the device booting time is reduced.
Mode: Global Config Mode
Privilege Level: Administrator
Format: selftest ramtest
776
Meaning
Configure the action for task errors.
Configure the action for lack of resources.
Configure the action for broken software
integrity.
Configure the action for detected hardware
errors.
Write a message to the logging file.
Send a trap to the management station.
Reboot the device.
70.1 selftest
RM CLI HiOS-2A GRS1040