MRP IEEE

54.1.3 mrp-ieee global leave-all-time

Set the IEEE multiple registration protocol leave-all time-interval. The leave
all timer controls the frequency with which the leaveall state machine gene-
rates leaveall PDUs. The timer is required on a per-Port, per-MRP Participant
basis.
Mode: Interface Range Mode
Privilege Level: Operator
Format: mrp-ieee global leave-all-time <P-1>
Parameter Value
200..6000
P-1
RM CLI HiOS-2A GRS1040
Release 6.1 09/2016
Meaning
Leave-All time-interval in centi-seconds.