Herunterladen Diese Seite drucken

Rmon-Alarm Modify - Hirschmann HiOS-2A GRS1040 Referenzhandbuch

Greyhound switch
Vorschau ausblenden Andere Handbücher für HiOS-2A GRS1040:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Remote Monitoring (RMON)

68.1.5 rmon-alarm modify

Modify RMON alarm parameters.
Mode: Global Config Mode
Privilege Level: Operator
Format: rmon-alarm modify <P-1> [mib-variable <P-2>]
[rising-threshold <P-3>] [falling-threshold <P-4>]
[interval <P-5>] [sample-type <P-6>] [startup-alarm
<P-7>] [rising-event <P-8>] [falling-event <P-9>]
[mib-variable]: Enter the alarm mib variable.
[rising-threshold]: Enter the alarm rising threshold.
[falling-threshold]: Enter the alarm falling-threshold.
[interval]: Enter the alarm interval in seconds over which the data is
sampled.
[sample-type]: Enter the alarm method of sampling the selected variable.
[startup-alarm]: Enter the alarm type.
[rising-event]: Enter the alarm rising-event index.
[falling-event]: Enter the alarm falling-event index.
Parameter Value
1..150
P-1
string
P-2
1..2147483647
P-3
1..2147483647
P-4
1..2147483647
P-5
absoluteValue
P-6
deltaValue
risingAlarm
P-7
fallingAlarm
risingOrFallingAlarm Single Rising alarm generated when the
764
Meaning
Enter an index that uniquely identifies an
entry in the alarm table.
Enter an object identifier of the particular
variable to be sampled, max. 32 characters.
Enter the rising threshold for the sampled
statistic.
Enter the falling threshold for the sampled
statistic.
Enter the interval in seconds over which the
data is sampled and compared with the rising
and falling thresholds.
Variable is compared directly with the
thresholds.
Variable is subtracted from the current
value and the difference compared with the
thresholds.
Single rising alarm generated when the
sample is greater than or equal to the rising
threshold.
Single falling alarm generated when the
sample is less than or equal to the falling
threshold.
sample is greater than or equal to risingT-
hreshold and single falling alarm generated
when the sample is less than or equal to fal-
lingThreshold.
68.1 rmon-alarm
RM CLI HiOS-2A GRS1040
Release 6.1 09/2016

Werbung

Kapitel

loading