Functions

8
Functions
8.1

Start of the timer

Movements of the gun actuators!
Bruises possible!
Therefore, make sure that can be damaged by movements of the gun
actuators no one.
It will go through the following sequence:
• 1. Wait until all internal IO drivers and the ProfiNet field bus are running.
• 2. Supply MGDM with voltage. (optocoupler)
It is checked if the input bit "Controller enable off" is not set and
the selected gun number is > 0.
If both conditions are fulfilled, the digital output "MGDM On" is
set and thus the optocoupler to the MGDM is enabled.
If the control mode is set to "PRI7000 user interface" (manual
mode), the optocoupler is not controlled at this point.
• 3. Load gun data:
The gun data of the tong number present at the IO field are
loaded. (Service program xx03_LoadGunData).
If no gun number is present (gun number = 0), the start
sequence is terminated.
In this case, a point selection > 0 would lead to a point selection
error, since there is no assignment to a gun. (Error 31023
"Activated channel and spot channel different").
If the control mode is set to theb "PRI7000 user interface"
(manual mode), the start sequence is terminated at this point.
• 4. Activate gun:
It is checked whether the input bit "Controller enable off" is set.
If the condition is fulfilled, the gun is activated (service program
xx01_Activate-Gun).
If a condition is not fulfilled, the start sequence is terminated.
The gun changes to the 7th axis operation when the positioning
authority is switched off. If a validly set position setpoint is
present which deviates from the actual position by > 5mm, the
error message "Position setpoint difference" may occur if the
position setpoint monitoring is activated (recommended).
After activating the drive, the drive should be set to AF (in
control).
• 5. End start sequence
8.2

Spot selection

8.2.1

8.2.1 Function description

• The IO length of the spot number is 2 bytes (0...65535), the IO length of the
vehicle type is 1 byte (0...255).
• For spots that are necessary to operate the system (service programs), the
point names are headed with an S_ (Ex: S_0_1101_ActivateGun) followed by a
R911405944 | PRC 7x00-Lx/Wx-0200