Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch Rexroth PRC 7 00-L /W -0200 Serie Typspezifische Anleitung Seite 70

Kombi-steuerung
Vorschau ausblenden Andere Handbücher für Rexroth PRC 7 00-L /W -0200 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

70/88
Bosch Rexroth AG
Functional description KE (Combi-control)
No.
PRC7000 outputs
71
Tip dress not ok
72
Not used
73
Tip / geometry fault
74
Contouring error
75
Not used
76
Error in the drive controller
77
Transformer Temperature fault
78
Fault Temperature gun motor
79
General error
80
Weld complete
Description
• The system reports that the tip dressing was not OK (an
impermissible dressing length was detected during
measurement).
• Hint: Set for the following error message when measuring after
dressing:
14013 Error tip dress length.
• The system reports that the geometry check has detected an error
after the tip change.
• The system also reports this error if the electrode break off
occurs.
• Note: Set for the following error messages:
14014 Error geometry test
14008 tip demolation
• The system reports that the gun has an internal tracking error.
• Note: Set for the following error messages:
14029 position command difference
An F2037 excessive position setpoint deviation may be set on
the drive as a subsequent error.
• The system reports a drive error. (The gun control or the
servocontroller report an error).
• Set for the following error message:
14009 Error in drive control
• The system reports that the temperature of the transformer is too
high or the temperature sensor is defective.
• Note: Set when the following error message occurs:
20023 Transformer temperature
• The system reports that the temperature of the motor is too high
or the temperature sensor is defective.
• Not resettable by "Reset fault".
• Note: Set in case of the following error message:
14036 Motor temperature shutdown
Error can be acknowledged as soon as the temperature is back
in the parameterized range.
Temperature prewarning / temperature sensor
defect are explicitly not set to this bit.
There is a fault.
This signal is also set for faults that are explicitly indicated on the
interface.
Resettable with "Reset fault". If the system is error-free, the error
status of the system is reset.
The started process is finished and the result is available on the
interface. The signal becomes active at the end of the welding cycle
and remains active until the start signal is reset.
R911405944 | PRC 7x00-Lx/Wx-0200

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis