72/88
Bosch Rexroth AG
Functional description KE (Combi-control)
No.
PRC7000 outputs
100
Welding not ok
101
Warning limit consecutively
violated
Not used
102
103
Difference current monitoring
triggered
104
Mains voltage off / too low
105
Primary over current
106
Error current sensor
107
Error voltage sensor
Not used
108
Description
Is set after a completed welding process in which errors have
occurred.
Is set in the corresponding error case (number of errors in
succession) and remains set until error acknowledgement.
Set for the following error messages:
- 41046 sequence of conditional errors
Signal is set when e.l.c.b. (earth leakage circuit breaker) has
tripped.
Note: Set when the following error message occurs:
- 11000 Residual Current Circuit Breaker open
- Bit is also set when the input of the Residual-Current Circuit
Breaker
open is not set.
The system reports that one or more phases are missing.
Note: Set for the following error messages:
• 20010 Mains voltage off
• 20013 Mains voltage low
• 20015 Mains phase off
The system reports that a corresponding fault message has been
registered.
The message remains set until the fault is acknowledged.
Note: Set for the following error messages:
• 31000 Power unit current too high
The system reports that a corresponding error message has been
registered. The message remains set until the error is
acknowledged.
Note: Set for the following error messages:
• 46001 Shortcut current measuring circuit
• 20027 Current measuring circuit open
• 41025 Default monitoring current too low
• 31007 Difference primary current measurement
• 41032 Current deviation Measuring Gun Data Module
• 31001 Sequence without current
The system reports that a corresponding error message has been
registered.
The message remains set until the error is acknowledged.
Notice:
Set for the following error messages:
• 31003 Voltage measurement circuit
R911405944 | PRC 7x00-Lx/Wx-0200