Networking and configuring the EV charging box
Prerequisite
96
Operating instructions – AC SMART
Managing RFID tags
RFID tags can be registered, authorised, blocked and deleted.
To register a new RFID tag, proceed as follows:
► Click RFID.
► In the Learn new tag field, click Start.
► Hold the RFID tag in front of the interaction area of the EV charging box
within 60 seconds.
After registration is complete, you will hear a confirmation signal.
► Click Refresh.
The ID of the detected RFID tag is displayed in the field Last found tag and
in the tag list. The status Accepted is displayed in the Status selection field.
► If you want to assign the ID a name, enter it in the list.
► If you want to block a registered RFID tag, change its status in the Status
selection field.
► Click Save.
To delete a registered RFID tag, you can execute an unlearn process or
delete the tag from the tag list.
Unlearn Tag
► Click RFID.
► In the Unlearn tag field, click Start.
► Hold the RFID tag in front of the interaction area of the EV charging box
within 60 seconds.
After deletion is complete, you will here a confirmation signal.
► Click Refresh.
The RFID tag is no longer displayed in the tag list.
Deleting from the tag list
► Click Delete beside the RFID tag you want to delete.
The RFID tag is no longer displayed in the tag list.
Configuring digital inputs
You must be logged in as an Admin. Electrician only!
You can configure the digital inputs for the following functions:
– Release charging process via external switching device (charging
authorisation)
– Restricting the charging current (current limitation)
If the digital input is active, the maximum charging current according to the
setting is made available. When the setting is at 100%, the maximum charg-
ing current is used; when the setting is at 0%, there is no charging at all.
► Click Config/Input.
► Change the function of the desired digital input.
► Activate the function.
► Activate Input monitoring if necessary.
► Click Save.
You can view the current switching status of the digital inputs in the Status
field. If there is a signal at an input, a tick mark is added to the status field.