Troubleshooting
Error ID
Description
30
The connection to the satellite box
was disconnected.
31
No secure OCPP connection
possible.
32
The internal memory is not
accessible.
33
The firmware will be updated.
35
There is an error in the internal
wireless modem.
114
Operating instructions – AC SMART
Recommended action
► Check the connection to the satellite box.
► Contact an electrician or the provider of your
OCPP backend.
► Switch off the residual current circuit breaker.
► Switch the residual current circuit breaker back
on after 10 seconds.
► Wait until the status LED is illuminated green.
► If the error occurs again, contact an electrician.
► Wait until the firmware update is complete.
► Switch off the residual current circuit breaker.
► Switch the residual current circuit breaker back
on after 10 seconds.
► Wait until the status LED is illuminated green.
► If the error occurs again, contact an electrician.
► If you are not using a Weidmüller SIM card,
check the settings in the web server.
► Check whether the selected reception type is
available at the setup location for the EV charg-
ing box.
► Disconnect the EV charging box from the power
supply.
► Check the fit of the SIM card.
► Connect the EV charging box to the power
supply.