Networking and configuring the EV charging box
Prerequisite
92
Operating instructions – AC SMART
9.3
Configuring the EV charging box in the web
server
The electrical configuration of the EV charging box may only be carried out by
an electrician.
Access to the web server is password protected, and there are two user
roles with different rights. The electrician must log in as an Admin in order
to complete the electrical configuration of the EV charging box. Operators or
users of the EV charging box can change certain settings using the role User.
Starting up the web server
To start the web server, the EV charging box must be connected to a local
network via LAN cable and the network settings must be adjusted, see Chap-
ter 9.1 and Chapter 9.2. A laptop or mobile device must also be connected to
the network.
► Open a web browser.
► Enter the IP address of the EV charging box in the address line:
http://192.168.0.8
The web server will be started up. Your login data will be requested.
The following login data apply on delivery:
– Role: Admin
– Password: zyVt45Nv0y
– Role: User
– Password: Detmold01
► Select the role and enter the password.
► Confirm the input.
The status page of the web server is displayed.
Figure 9.5
Status page of the web server
To prevent unauthorised access, you should change the password immedi-
ately. Observe the local data security regulations.