Connection via Modbus TCP (WLAN)
Prerequisite
To use the Modbus TCP interface via WLAN, the EV charging box must be
connected to a WLAN network, see Chapter 9.3.
► Start the web server of the EV charging box.
► Click Config/General.
► Change the desired function (Modbus TCP).
► Click Save.
The change is adopted the next time the EV charging box is restarted.
► Click Restart.
Connection via Modbus RTU
The EV charging boxes in the AC SMART product family can be connected
via interfaces X5.1 and X5.2 on the control board in the housing cover in a
Modbus RTU network (RS485). Upon delivery, the Modbus RTU interface is
configured as follows:
Address
Speed
Parity
In the VALUE and ADVANCED product lines, the RTU interface has a switch-
able terminating resistor. The terminating resistor is activated as a default.
► Connect the external device to the Modbus RTU interface (X5.1 and X5.2)
of the control board in the housing cover.
► Start the web server, see Chapter 9.3.
► Click Config/Modbus RTU server.
► Change the values.
► Click Save.
The change is adopted the next time the EV charging box is restarted.
► Click Restart.
Also observe the Modbus register. The tables are available in our online
catalogue.
Networking and configuring the EV charging box
100
19200
None
Operating instructions – AC SMART
101

Werbung

loading