Error ID
Description
9
The charging plug on the EV charging
box cannot be interlocked.
10
The charging plug on the EV charging
box cannot be released.
11
The vehicle exceeds the current limit.
The charging process is ended.
12
The internal temperature sensor has
detected that the temperature in the
EV charging box is too high. The
charging process was cancelled to
prevent damage.
Recommended action
► Remove the charging plug from the charging
socket on the EV charging box.
► Disconnect the EV charging box from the power
supply.
► Check the charging plug and charging socket for
contamination.
► Remove slight contamination yourself, or com-
mission an electrician to carry out cleaning, see
Chapter 11.
► Connect the EV charging box to the power
supply.
► Connect the vehicle to the EV charging box once
again. Ensure the charging plug is connected
correctly.
► Start the charging process.
► If the error occurs again, contact an electrician.
► Check whether the charging plug has become
tilted or if there is some other mechanical load.
► Switch off the residual current circuit breaker.
► Switch the residual current circuit breaker back
on after 10 seconds.
► If the error occurs again, contact an electrician.
► Restart the charging process.
► If the error occurs again, contact the vehicle
manufacturer.
► Disconnect the vehicle from the EV charging box.
► Once the EV charging box has cooled down, the
error will be reset.
► If the error occurs frequently or the error is not
automatically reset, contact an electrician.
► Observe the permitted ambient conditions in the
technical data, see chapter 15.
► If the permitted ambient conditions are complied
with and the error occurs again, contact Weid-
müller Service.