o) Beep tones when output #1 is activated - programming code 72
When output #1 is activated for the door opener (e.g. when a valid user code is entered), the
code lock emits a long beep tone in basic setting.
This tone is normally used to signal that the door opener is activated (especially for
door openers that do not make a noise when they are activated).
If desired, you can change the beep tone to two short beeps or disable it entirely (e.g. when
using the lock in a quiet office or at night).
Setting the beep tones when output #1 is activated:
• The code lock should be in programming mode, see Chapter 14. b).
• General input for programming:
Programming code
• Programming code 72
• Mode selection:
No beep tones
One long beep tone (default setting)
Two short beeps
• Confirmation:
Press the
button to confirm your entry. The code lock emits two beep tones and the centre
LED flashes twice orange. Programming is saved.
• When you have finished programming, exit programming mode with the
Programming example: Select the notification tone
(a)
(b)
(c)
(a) Programming code 72
(b) Two short beep tones activate "2".
(c) Save programming (code lock emits two beep tones and the centre LED flashes twice
orange)